Description
The GE RS-FS-9001 362A1052P404 is a sophisticated fire and smoke detection module designed as a critical component within GE’s comprehensive line of industrial safety and security systems. This device serves as the frontline sentinel, continuously monitoring a protected area for the earliest signs of fire—specifically both smoke particulates and flame signatures. As part of the GE security and fire alarm portfolio, the core function of the GE RS-FS-9001 362A1052P404 is to provide rapid and reliable detection, converting a physical phenomenon (smoke or flame) into a precise electrical signal that is communicated to a central fire alarm control panel (FACP). This enables immediate alarm activation and initiation of emergency protocols, such as releasing fire suppression systems or initiating facility evacuation.
The GE RS-FS-9001 362A1052P404 is engineered for high-value industrial, commercial, and infrastructure applications where false alarms can be costly and missed alarms can be catastrophic. Its value proposition lies in its advanced sensing technology, which is designed to distinguish between genuine fire events and nuisance sources, thereby ensuring a high degree of operational stability and trust. The module is built to meet rigorous industrial standards, often featuring robust housing to withstand challenging environmental conditions like dust, humidity, and temperature fluctuations. The integration of the GE RS-FS-9001 362A1052P404 into a larger safety ecosystem makes it an indispensable asset for protecting personnel, critical processes, and valuable infrastructure from the devastating impact of fire.

GE RS-FS-9001 362A1052P404
Technical Specifications
| Parameter Name | Parameter Value |
| Product Model | RS-FS-9001 / 362A1052P404 |
| Manufacturer | GE (General Electric) |
| Product Type | Fire and Smoke Detection Module |
| Detection Principle | Photoelectric for Smoke, Infrared for Flame |
| Voltage Range | Typically 15-32 VDC (compatible with standard fire panel loops) |
| Current Draw | Standby and alarm currents as per manufacturer datasheet |
| Communication | Via the fire alarm loop to the compatible GE control panel |
| Alarm Indication | Internal LED and relay change-of-state signal to the panel |
| Operating Temperature | -10°C to +55°C (14°F to 131°F) or wider industrial range |
| Humidity Range | 0% to 95% Relative Humidity, non-condensing |
| Housing Protection | IP rating suitable for indoor industrial environments (e.g., IP54) |
| Compatibility | Designed for GE MXL, EST3, or other GE fire alarm systems |
Main Features and Advantages
Dual-spectrum detection capability is a key feature of the GE RS-FS-9001 362A1052P404. By combining photoelectric smoke sensing with infrared flame detection, it offers a broader and more reliable coverage of fire types. The photoelectric chamber is highly sensitive to visible smoke particles from smoldering fires, while the IR sensor can quickly detect the flickering frequency of flames, providing a fast response to open, flaming fires. This dual-technology approach significantly enhances detection reliability and reduces the probability of nuisance alarms caused by dust or steam, which might trigger a single-technology detector.
Robust construction and seamless integration are fundamental advantages. The GE RS-FS-9001 362A1052P404 is built with industrial durability in mind, featuring a housing that protects its sensitive internal components from contaminants and physical damage. Its design ensures easy installation and maintenance, often featuring a plug-in base that simplifies wiring and replacement. Furthermore, the module is engineered for flawless integration with GE’s fire alarm control panels. It communicates its status (normal, alarm, trouble) directly to the panel, allowing for centralized monitoring and control. The GE RS-FS-9001 362A1052P404 may also include features like automatic self-testing and drift compensation to maintain sensitivity over time, ensuring long-term performance and compliance with fire safety standards without requiring constant manual calibration.
Application Field
The GE RS-FS-9001 362A1052P404 is deployed across a wide spectrum of facilities where early and reliable fire detection is non-negotiable for safety and asset protection. Its robust design makes it suitable for environments that are beyond the scope of standard commercial detectors.
In industrial settings, the GE RS-FS-9001 362A1052P404 is essential for protecting manufacturing plants, chemical processing facilities, and power generation stations. It is often installed in high-bay areas, warehouses storing combustible materials, and along production lines where electrical or thermal processes present a fire risk. Within critical infrastructure, this detector is a key component in telecommunications data centers, water treatment plants, and transportation hubs like airports and train stations, where system downtime must be minimized. The GE RS-FS-9001 362A1052P404 is also widely used in commercial buildings such as high-rise offices, hospitals, and shopping malls, providing life safety coverage for atriums, electrical rooms, and equipment corridors. Its ability to provide dual-spectrum detection makes it particularly valuable in areas where both smoldering and flaming fires are potential risks.
GE RS-FS-9001 362A1052P404
Related Products
GE Fire Alarm Control Panel (e.g., MXL Series): The central brain of the system that receives and processes signals from the GE RS-FS-9001 362A1052P404.
GE MM-1 Monitor Module: A supporting module that can monitor conventional dry contacts and integrate them into the same system as the RS-FS-9001.
GE CMX-1 Control Module: A module used to control external devices like fans or door holders based on alarms from detectors like the 362A1052P404.
GE HCH-HP Heat Detector: A complementary detector for areas where smoke detection is not suitable, used alongside the GE RS-FS-9001.
GE S-Quad Detector Base: The likely mounting base that provides power and communication loop connection for the GE RS-FS-9001 362A1052P404 module.
GE 362A1052P403 / 362A1052P405: Likely variants of the same detector series with different sensitivities or slightly different functional specifications.
System Audio Visual Evacuation Devices: Horns and strobes that are activated by the control panel upon an alarm signal from the RS-FS-9001.



Email: sales@slxytech.com