Description
The TEWS TPMC815-11 is a high-performance clock generator module designed to provide precise timing and synchronization signals for industrial automation and embedded systems. This advanced clock generation solution delivers exceptional signal integrity and timing accuracy, making it ideal for applications requiring precise clock distribution and synchronization across multiple system components. The TPMC815-11 incorporates sophisticated phase-locked loop (PLL) technology and low-jitter clock synthesis capabilities, ensuring reliable performance in demanding industrial environments.Engineered with flexibility in mind, the TEWS TPMC815-11 supports multiple clock output configurations and frequency ranges, allowing customization to meet specific system requirements. The module’s robust design features enhanced electromagnetic compatibility (EMC) performance and operates reliably across extended temperature ranges. As part of TEWS’ comprehensive PMC module family, the TPMC815-11 seamlessly integrates with standard carrier boards, providing a compact yet powerful timing solution for various embedded computing applications.The module’s advanced features include programmable output frequencies, clock monitoring capabilities, and fail-safe operation modes, making the TEWS TPMC815-11 suitable for critical applications where timing precision is essential. Its compatibility with industry-standard interfaces ensures easy integration into existing systems while maintaining the high reliability expected from TEWS products.

TEWS TPMC815-11
Technical Specifications
| Parameter Name | Parameter Value |
| Product Model | TPMC815-11 |
| Manufacturer | TEWS Technologies |
| Product Type | Clock Generator Module |
| Form Factor | PMC (PCI Mezzanine Card) |
| Frequency Range | 1MHz to 200MHz (programmable) |
| Output Channels | 8 differential clock outputs |
| Output Types | LVPECL, LVDS, HCSL compatible |
| Jitter Performance | <1ps> |
| Phase Noise | -150 dBc/Hz at 100kHz offset |
| Reference Input | 10MHz to 40MHz external reference |
| Holdover Accuracy | ±4ppb in holdover mode |
| Power Supply | 3.3V ±5% |
| Power Consumption | <2W> |
| Operating Temperature | -40°C to +85°C |
| Storage Temperature | -55°C to +125°C |
| MTBF | >100,000 hours |
| Compliance | PCI Industrial Computers Manufacturers Group |
Main Features and Advantages
The TEWS TPMC815-11 incorporates several advanced features that ensure superior timing performance and system reliability. The module’s high-precision clock synthesis technology generates ultra-low jitter clock signals, which is critical for maintaining signal integrity in high-speed digital systems. This exceptional jitter performance makes the TPMC815-11 particularly valuable in applications requiring precise timing, such as data acquisition systems, telecommunications equipment, and test measurement instruments.Flexible configuration capabilities represent a significant advantage of the TPMC815-11 clock generator. The module supports programmable output frequencies through software control, allowing dynamic adjustment to meet changing system requirements. Each of the eight output channels can be independently configured for different frequencies and signal formats, providing unprecedented flexibility in clock distribution design. The module’s automatic failover and holdover capabilities ensure continuous operation even when the primary reference clock is lost.Robust construction and environmental resilience make the TEWS TPMC815-11 suitable for demanding industrial applications. The module operates reliably across the extended industrial temperature range and withstands mechanical stress and vibration typical in industrial environments. Comprehensive monitoring and diagnostic features provide real-time status information, enabling proactive maintenance and reducing system downtime. The module’s standard PMC form factor ensures compatibility with a wide range of carrier boards, simplifying system integration and reducing development time.
Application Field
The TEWS TPMC815-11 finds essential application in telecommunications infrastructure equipment where precise timing synchronization is critical for network operation. In base station controllers and network synchronization units, the module provides the accurate clock signals necessary for maintaining synchronization across distributed network elements. The TPMC815-11‘s holdover capability ensures stable operation during temporary loss of reference signals, maintaining network stability and preventing service disruptions.In industrial automation systems, the clock generator serves as the timing heart for distributed control systems and real-time data acquisition platforms. The TEWS TPMC815-11 ensures synchronized operation across multiple processing nodes and I/O modules, enabling precise coordination of control actions and accurate timestamping of process data. This synchronization capability is particularly valuable in motion control applications and high-speed manufacturing processes where timing precision directly impacts product quality and production efficiency.For test and measurement equipment, the TPMC815-11 provides the clean clock signals required for accurate signal generation and analysis. The module’s low jitter characteristics ensure precise timing in oscilloscopes, spectrum analyzers, and automated test systems, enabling accurate measurements and reliable test results. The programmability of the clock generator allows test equipment manufacturers to create versatile instruments that can be adapted to various measurement scenarios and standards.

TEWS TPMC815-11
Related Products
•TPMC815-12 – Enhanced version with additional output channels
•TPMC810-11 – Basic clock generator with reduced channel count
•TPMC820-11 – Multi-purpose I/O module with clocking capabilities
•TPMC830-11 – Communication module with integrated timing
•TPMC840-11 – DSP module for signal processing applications
•TPMC850-11 – Storage module with timing synchronization
•TPMC860-11 – Network interface module with precision timing
Installation and Maintenance
Installation preparation: Before installing the TEWS TPMC815-11, verify compatibility with the carrier board and ensure proper handling to prevent electrostatic discharge. The module should be installed in a clean environment with appropriate anti-static precautions. Confirm that the carrier board provides adequate power supply capacity and proper cooling for the clock generator module. Review the system design to ensure correct clock distribution layout and impedance matching for optimal signal integrity.Maintenance recommendations: Regular maintenance of the TPMC815-11 includes monitoring operating temperature and ensuring adequate airflow around the module. Periodically verify clock signal quality using appropriate test equipment to detect any degradation in performance. Maintain current firmware versions and backup configuration settings to facilitate quick recovery in case of module replacement. For systems operating in critical applications, consider implementing redundant clock sources using the module’s reference switching capabilities.



Email: sales@slxytech.com
WhatsApp / Wechat:8617062388866
Phone:+86 17062388866