WESTINGHOUSE 1C31125G02- Compatible with Ovation I/O electronic modules, seamlessly integrated!

The Westinghouse 1C31125G02 is a high-capacity, redundant power supply module engineered for Emerson’s Ovation™ distributed control system (DCS), carrying forward Westinghouse Electric’s legacy of industrial-grade reliability. Designed to energize critical control racks in demanding environments, this module delivers 60A of stabilized +5V DC power alongside auxiliary voltages, ensuring uninterrupted operation for high-density I/O subsystems and controller networks. Its N+1 parallel redundancy architecture allows seamless load sharing and hot-swap capability, eliminating single points of failure during grid disturbances or maintenance. The Westinghouse 1C31125G02 features advanced active power factor correction (>0.95) and multi-stage filtration, protecting sensitive electronics from harmonics and voltage transients. As a cornerstone of Ovation’s safety-certified platforms (up to SIL 3), it meets stringent nuclear and fossil power generation requirements. Robust construction includes conformal-coated circuitry for humidity resistance (up to 95% non-condensing) and seismic-compliant mounting. Backward-compatible with legacy Westinghouse WDPF II systems, the Westinghouse 1C31125G02 bridges historical investments with modern operational resilience.

Manufacturer:
Our extensive catalogue, is available now for dispatch to the worldwide.
  • Email: sales@slxytech.com
  • WhatsApp / Wechat:8617062388866
  • Phone:+86 17062388866

Description

The Westinghouse 1C31125G02 is a high-capacity, redundant power supply module engineered for Emerson’s Ovation™ distributed control system (DCS), carrying forward Westinghouse Electric’s legacy of industrial-grade reliability. Designed to energize critical control racks in demanding environments, this module delivers 60A of stabilized +5V DC power alongside auxiliary voltages, ensuring uninterrupted operation for high-density I/O subsystems and controller networks. Its N+1 parallel redundancy architecture allows seamless load sharing and hot-swap capability, eliminating single points of failure during grid disturbances or maintenance. The Westinghouse 1C31125G02 features advanced active power factor correction (>0.95) and multi-stage filtration, protecting sensitive electronics from harmonics and voltage transients. As a cornerstone of Ovation’s safety-certified platforms (up to SIL 3), it meets stringent nuclear and fossil power generation requirements. Robust construction includes conformal-coated circuitry for humidity resistance (up to 95% non-condensing) and seismic-compliant mounting. Backward-compatible with legacy Westinghouse WDPF II systems, the Westinghouse 1C31125G02 bridges historical investments with modern operational resilience.

WESTINGHOUSE 1C31125G02

WESTINGHOUSE 1C31125G02

Technical Specifications

Parameter Name Parameter Value
Product Model 1C31125G02
Manufacturer Westinghouse (Emerson Ovation)
Product Type High-Current Redundant Power Supply
Input Voltage 100-240V AC (Auto-ranging), 47-63 Hz
Output Ratings +5V DC @ 60A, +12V DC @ 10A, -12V DC @ 5A
Efficiency 88% (Typical, 50-100% load)
Redundancy Parallel N+1 with Active Current Sharing
Hot Swap Supported (Live insertion/removal)
MTBF 300,000 hours (Per MIL-HDBK-217F)
Operating Temperature -10°C to 70°C (14°F to 158°F)
Cooling Dual Ball-Bearing Fans (Speed-controlled)
Safety/Certifications UL 508, CE, IEC 61010-1, IEEE 344 (Seismic)
Dimensions 200 × 50 × 160 mm (7.9 × 2.0 × 6.3 in)
Weight 2.1 kg (4.6 lbs)

Main Features and Advantages

Ultra-High Power Density: The Westinghouse 1C31125G02 packs 300W of regulated power in a compact footprint, supporting high-density controller racks without derating. Proprietary current-balancing technology ensures equal load distribution across parallel units, preventing thermal hotspots.

Intelligent Diagnostics: Real-time monitoring of output ripple (<80mV>

Electromagnetic Robustness: Exceeds IEC 61000-4-5 (4kV surge) and IEC 61000-4-4 (EFT 40A) immunity standards. Shielded design minimizes EMI emissions (EN 55032 Class A), critical for substation environments.

Resilient Engineering: Copper bus-bar output connections (vs. cabling) reduce impedance and enhance vibration resistance. Conformal coating protects against conductive dust and corrosive gases. Dual fans with speed modulation ensure optimal thermal management across operating loads.

Operational Flexibility: Universal AC input (85-264V AC) with inrush current limiting (<40A>

Application Field

The Westinghouse 1C31125G02 powers mission-critical automation where downtime is unacceptable:

 

Power Generation: Feeds Ovation controllers managing gas/coal turbine protection, boiler combustion safety (NFPA 85/86), and grid synchronization in combined-cycle plants. Nuclear applications leverage its IEEE 344 seismic qualification.

 

Oil & Gas: Provides fault-tolerant power for offshore platform ESD systems, compressor station control, and LNG cryogenic process safety loops (-40°C capable).

 

Water/Wastewater: Energizes SCADA networks controlling high-lift pumps and chemical dosing systems, immune to voltage dips from motor startups.

 

Heavy Industry: Supports rolling mill automation, mining conveyor safety circuits, and metallurgical process controls exposed to conductive dust.

 

Renewables: Integrates with battery energy storage (BESS) controllers for grid-forming inverters in solar/wind farms.

WESTINGHOUSE 1C31125G02

WESTINGHOUSE 1C31125G02

Related Products

 

1C31122G01: 40A base model for standard-density racks

 

1C31125G03: Successor model with enhanced diagnostics

 

1C31194G01: Power Distribution Panel (busbar assembly)

 

5X00070G01: Ovation Controller Module (primary load)

 

1C31203G01: Redundant Fan Tray Assembly

 

1C31181G01: 12-Slot Ovation Chassis Backplane

 

Ovation VPU: Virtualization platform for legacy hardware emulation

 

1C31129G01: 24V DC-input model for battery backup systems

 

Installation and Maintenance

Pre-installation preparation: Verify chassis slot compatibility (Ovation Pxxx-series racks). Ensure rack grounding resistance <0>

Maintenance recommendations: Monitor output voltage stability quarterly via Ovation diagnostics. Clean air intake filters monthly in high-particulate environments. Replace both fans preventatively at 60,000 hours. During hot-swap, engage rack’s extraction handle fully to trigger backplane isolation before removal. Store spares at 15-35°C with 30-70% RH.